Buenas,
cual es la configuracion necesaria para conectar por serie a un forti 50B ??
No logro establecer conexion y he probado las configuraciones habituales.
Gracias
Acceso por puerto serie
Re: Acceso por puerto serie
hola, conectar por serie ?? usando hyperterminal ???
Components
* a null modem, or RJ-45 to DB9 console cable (supplied with the FortiGate unit). See also the related article Serial cable pinouts for console access to Fortinet devices
* an Ethernet RJ45 cable
* a terminal client, such as a PC running HyperTerminal (Windows)
Terminal client communication parameters
8 bits
no parity
1 stop bit
9600 baud (the FortiGate-300 uses 115,000 baud)
Flow Control = None
saludos
Components
* a null modem, or RJ-45 to DB9 console cable (supplied with the FortiGate unit). See also the related article Serial cable pinouts for console access to Fortinet devices
* an Ethernet RJ45 cable
* a terminal client, such as a PC running HyperTerminal (Windows)
Terminal client communication parameters
8 bits
no parity
1 stop bit
9600 baud (the FortiGate-300 uses 115,000 baud)
Flow Control = None
saludos
NSE 7 – Fortinet Network Security Architect
NSE 5 - Network Security Analyst
NSE 5 - Network Security Analyst
Re: Acceso por puerto serie
hola, de nada
saludos
saludos
NSE 7 – Fortinet Network Security Architect
NSE 5 - Network Security Analyst
NSE 5 - Network Security Analyst